https://doi.org/10.1140/epjd/e2017-80115-9
Regular Article
Comparing the biocidal properties of non-thermal plasma sources by reference protocol
Department of Physics and Measurements, University of Chemistry and Technology,
Prague, Czech Republic
a e-mail: scholtzv@vscht.cz
Received:
19
February
2017
Received in final form:
1
August
2017
Published online: 19
October
2017
The previously proposed reference protocol enabling easy comparison of biocidal properties of different non-thermal plasma sources has been followed and discussed. For inactivation tests the reference protocol has used spores of Gram positive bacterium Bacillus subtilis (ATCC 6633) deposited on a polycarbonate membrane as reference sample. In this work, biocidal properties of a negative glow corona, positive streamer corona, positive transient spark and cometary discharges are being compared in both open air and closed apparatus. Despite the total number of bacteria surviving 1 h exposure has decreased by up to 7 orders in closed apparatus, in open one, only weak inhibition bactericidal effect has been observed.
Key words: Plasma Physics
© EDP Sciences, Società Italiana di Fisica, Springer-Verlag 2017