Lifetime measurements for some n = 2 levels in Be-like Cl XIV and S XIII
Tata Institute of Fundamental Research,
Homi Bhabha Road, Mumbai 400 005, India
Corresponding author: a nb@tifrvax.tifr.res.in
Received:
29
October
1997
Revised:
10
February
1998
Accepted:
5
March
1998
Published online: 15 May 1998
Lifetime measurements have been carried out for some low lying (n =
2) levels in the four-electron ions Cl XIV and S XIII using the
beam-foil technique. Accurate oscillator strengths for the transition have been determined by the inclusion of
prominent cascades in the analysis. Lifetimes of the levels of the
multiplet have also been measured for both ions. The
results are compared with theoretical predictions and earlier
measurements.
PACS: 32.70.Cs – Oscillator strengths, lifetimes, transition moments